            HOME > Product Center > Transformer > Switching transformer > Switch transformer :(PQ series)

            Switch transformer :(PQ series)

            Characteristic

            The above transformers are widely used in switching power supply and have the following characteristics:

            Use frequency:25-500kHZ

            Power range:10-500W

            High permeability, high efficiency, low leakage, good heat dissipation, small electromagnetic interference

            Magnetic core:EE、EC、EI、EF、EER、ED、EFD、PQ、RM

            Magnetic core material:SP3、SP4、SP4A

            Installation: can be designed according to customer requirements


            Applications

            Various switching power supply: dc-dc, ac-dc-ac, dc-ac,UPS power supply, etc

            Circuit form: forward excitation, back excitation, push pull, half bridge, full bridge circuit, etc

            Used for power supply of communication, TV, air conditioner and computer. Switching power supply in all kinds of electronic equipment。


            Switch transformer :(PQ series).pdf

            Download

            Additional Information

            image.pngimage.png

            Pq26/25 vertical 12-pin transformer  

            Pq32/20 vertical 12-pin transformer

            Series regular table

            Series specification sheet

            model

            A±2.0

            B±2.0

            D±2.0

            F±0.3

            H±0.3

            G±0.5

            PIN

            PQ2016-1

            23.5

            18.0

            23.5

            2.5/3.8

            5.0

            20.5

            6+8

            PQ2016-2

            23.5

            17.5

            23.5

            3.8

            5.0

            20.5

            6+6

            PQ2018-1

            23.5

            20.5

            23.5

            3.8

            5.0

            20.5

            6+6

            PQ2020-1

            23.3

            22.4

            23.1

            2.5/3.8

            5.0

            20.5

            6+8

            PQ2620

            27.2

            21.2

            29.1

            3.8

            7.5

            25.5

            6+6

            PQ2622.5

            27.8

            23.0

            29.5

            3.8

            7.5

            25.5

            6+6

            PQ2623

            27.8

            23.5

            29.5

            3.8

            7.5

            25.5

            6+6

            PQ2625

            28.3

            25.6

            29.5

            3.8

            7.5

            25.5

            6+6

            PQ3220

            32.5

            21.5

            34.2

            5.0

            7.5

            30.5

            6+6

            PQ3225

            32.5

            25.8

            34.0

            5.0

            7.5

            30.5

            6+6

            PQ3230

            32.9

            33.0

            34.4

            5.0

            7.5

            30.0

            6+6

            PQ3525

            36.0

            27.0

            39.5

            5.0

            10.0

            35.0

            6+6

            PQ3535

            36.0

            27.0

            39.0

            5.0

            9.5

            35.5

            6+6

            PQ4040

            40.4

            42.8

            42.1

            5.0

            15.0

            38.0

            6+6

            PQ5050

            51.2

            52.0

            51.4

            7.5

            12.5

            46.0

            6+6

            Lighting circuit magnetic device solution

            (1)A typical circuit

            In switching power supply circuits, the commonly used typical circuit topologies are:

            Forward - excited, back - excited, push - pull, half - bridge (full - bridge), etc。A typical three-way output forward converter topology is shown below。When the dc input voltage is 60-200v and the output power is 200W,Forward converter is probably the most widely used topology。

            image.png

             Three-terminal output forward converter topology

            The typical circuit diagram of flyback converter is shown below5-150w low cost power supply applicationsIs very extensive, and its greatest advantage isNo secondary output inductance is required。

             

            image.png

            Flyback converter topology

            The typical topology of a full-bridge converter is shown in the figure Input network pressure for 220V or higher applications,Its main advantage is that the leakage voltage spike clamp on the primary side of the transformer can be located at the dc bus voltage and the leakage energy can be fed back to the input bus。

            image.png 

            Full bridge converter topology

            Certification - quality assurance

            Adopt international standard quality system certification, safety system certification, so that customers in the use of greater quality and safety assurance